SetOverwrite {Cold Formed AISI ASD96}

SetOverwrite

Syntax

SapObject.SapModel.DesignColdFormed.AISI_ASD96.SetOverwrite

VB6 Procedure

Function SetOverwrite(ByVal Name As String, ByVal Item As Long, ByVal Value As Double, Optional ByVal ItemType As eItemType = Object) As Long

Parameters

Name

The name of an existing frame object or group depending on the value of the ItemType item.

Item

This is an integer between 1 and 27, inclusive, indicating the overwrite item considered.

1 = Framing type

2 = Live load reduction factor

3 = Unbraced length ratio, Major

4 = Unbraced length ratio, Minor and Lateral Torsional Buckling

5 = Effective length factor, K Major

6 = Effective length factor, K Minor

7 = Moment coefficient, Cm Major

8 = Moment coefficient, Cm Minor

9 = Moment coefficient, Ctf Major

10 = Moment coefficient, Ctf Minor

11 = Bending coefficient, Cb

12 = Moment factor, Alpha Major

13 = Moment factor, Alpha Minor

14 = Through fastened to deck

15 = Fastener eccentricity, a/b

16 = Hole diameter at top flange

17 = Hole diameter at bottom flange

18 = Hole diameter on web

19 = Yield stress, Fy

20 = Nominal compressive capacity, Pnc

21 = Nominal tensile capacity, Pnt

22 = Nominal bending capacity for yielding, Mn33

23 = Nominal bending capacity for yielding, Mn22

24 = Nominal bending capacity for lateral torsional buckling, Mn33

25 = Nominal bending capacity for lateral torsional buckling, Mn22

26 = Nominal shear capacity, Vn2

27 = Nominal shear capacity, Vn3

Value

The value of the considered overwrite item.

1 = Framing type

0 = Program Default

1 = Moment Frame

2 = Braced Frame

2 = Live load reduction factor

Value >= 0; 0 means use a program determined value.

3 = Unbraced length ratio, Major

Value >= 0; 0 means use program determined value.

4 = Unbraced length ratio, Minor and Lateral Torsional Buckling

Value >= 0; 0 means use program determined value.

5 = Effective length factor, K Major

Value >= 0; 0 means use program determined value.

6 = Effective length factor, K Minor

Value >= 0; 0 means use program determined value.

7 = Moment coefficient, Cm Major

Value >= 0; 0 means use program determined value.

8 = Moment coefficient, Cm Minor

Value >= 0; 0 means use program determined value.

9 = Moment coefficient, Ctf Major

Value >= 0; 0 means use program determined value.

10 = Moment coefficient, Ctf Minor

Value >= 0; 0 means use program determined value.

11 = Bending coefficient, Cb

Value >= 0; 0 means use program determined value.

12 = Moment factor, Alpha Major

Value >= 0; 0 means use program determined value.

13 = Moment factor, Alpha Minor

Value >= 0; 0 means use program determined value.

14 = Through fastened to deck

0 = No.

Any other value = Yes.

15 = Fastener eccentricity, a/b

Value >= 0; 0 means use program determined value. [L]

16 = Hole diameter at top flange

Value >= 0; 0 means use program determined value. [L]

17 = Hole diameter at bottom flange

Value >= 0; 0 means use program determined value. [L]

18 = Hole diameter on web

Value >= 0; 0 means use program determined value. [L]

19 = Yield stress, Fy

Value >= 0; 0 means use program determined value. [F/L
2
]

20 = Nominal compressive capacity, Pnc

Value >= 0; 0 means use program determined value. [F]

21 = Nominal tensile capacity, Pnt

Value >= 0; 0 means use program determined value. [F]

22 = Nominal bending capacity for yielding, Mn33

Value >= 0; 0 means use program determined value. [FL]

23 = Nominal bending capacity for yielding, Mn22

Value >= 0; 0 means use program determined value. [FL]

24 = Nominal bending capacity for lateral torsional buckling, Mn33

Value >= 0; 0 means use program determined value. [FL]

25 = Nominal bending capacity for lateral torsional buckling, Mn22

Value >= 0; 0 means use program determined value. [FL]

26 = Nominal shear capacity, Vn2

Value >= 0; 0 means use program determined value. [F]

27 = Nominal shear capacity, Vn3

Value >= 0; 0 means use program determined value. [F]

ItemType

This is one of the following items in the eItemType enumeration:

Object = 0

Group = 1

SelectedObjects = 2

If this item is Object, the assignment is made to the frame object specified by the Name item.

If this item is Group, the assignment is made to all frame objects in the group specified by the Name item.

If this item is SelectedObjects, assignment is made to all selected frame objects, and the Name item is ignored.

Remarks

This function sets the value of a cold formed design overwrite item.

The function returns zero if the item is successfully set; otherwise it returns a nonzero value.

VBA Example

Sub SetColdFormedDesignOverwriteItemAISI_ASD96()

'dimension variables

Dim SapObject as cOAPI

Dim SapModel As cSapModel

Dim ret As Long

Dim Name As String

'create Sap2000 object

Set SapObject = CreateObject("CSI.SAP2000.API.SapObject")

'start Sap2000 application

SapObject.ApplicationStart

'create SapModel object

Set SapModel = SapObject.SapModel

'initialize model

ret = SapModel.InitializeNewModel

'add cold formed material

ret = SapModel.PropMaterial.AddQuick(Name, MATERIAL_COLDFORMED, , , , MATERIAL_COLDFORMED_SUBTYPE_ASTM_A653SQGr50)

'create new cold formed frame section property

ret = SapModel.PropFrame.SetColdC("CdC", Name , 9, 3, 0.06, 0.25, 0.5)

'create model from template

ret = SapModel.File.New2DFrame(PortalFrame, 2, 72, 2, 144, True, "CdC", "CdC")

'set cold formed design code

ret = SapModel.DesignColdFormed.SetCode("AISI-ASD96")

'set overwrite item

ret = SapModel.DesignColdFormed.AISI_ASD96.SetOverwrite("8", 1, 2)

'close Sap2000

SapObject.ApplicationExit False

Set SapModel = Nothing

Set SapObject = Nothing

End Sub

Release Notes

Initial release in version 11.03.

See Also

GetOverwrite